GCE India has Medical Oxygen Equipment available CHECK IT OUT close
Home » Cylinder regulator for HCL_CL2

Cylinder regulator for HCL_CL2

CSLHHSQR3X – single stage cylinder regulator with external gas purging | Inner Parts NI-CR-MO-Alloy

Technical Specification:

  • Gas wetted internal parts are made of high-alloy stainless steel
  • Exclusively available with external gas purging on the inlet pressure side
  • Available with different cylinder connections according to national standards
  • Excellent pressure adjustment
  • Compact design
  • Pressure relief valve on outlet pressure side

TECHNICAL DATA

Working temperature: -20°C to +60°C
Leakage rate seat: <1x10-6 mbar l/s (Helium)
Leakage rate outside: <1x10-9 mbar l/s (Helium)
Filter: 1x for inlet
1x for each outlet
Flow nominal: 50 slpm (Cl2)
90 slpm (HCl)
Material gas wetted parts:  
   Regulator body: Stainless Steel
   Regulator diaphragm: Ni-Cr-Mo-alloy (UNS N06022)
   Regulator seat: PCTFE
   Regulator poppet: Ni-Cr-Mo-alloy (UNS N06022)
Pressure rates regulator:  
   Inlet pressure: 12 bar (Cl2)
50 bar (HCl)
   Outlet pressure: 0,1 – 2 bar adjustable
0,2- 7 bar adjustable
0,3- 10 bar adjustable
Pressure gauges rates (pressure rates): 2,5 (2) | 10 (7) | 18 (10/12) | 65 (50) bar
Cracking pressure relief valves: 3,1 (2) | 10 (7) | 15,4 (10) bar

 For more technical details please refer to the datasheet!